Series 4300 Totalizer

Featuring 5 digits of rate and 8 digits of total, the INVALCO 4300 is a battery- or loop-powered indicator capable of accepting magnetic pickup, DC pulse or switch closure inputs from pulse producing flowmeters. The unit can be ordered with an optional 4-20mA output (Models 4300-3I and 4300-3O). The 4300 uses the 4-20mA loop to provide power when this output is used.

Specifications

Power
Battery powered (Model 4300-3A) Supplied with 2 C size Lithium batteries.
Loop Powered (Models 4300-3I and 4300-3O) Voltage: 8.5 to 30 VDC
Supplied with 2 C size lithium batteries
Protection: Reverse Polarity Protection on Current Loop
Loop Burden: 8.5V maximum
Battery Life Expectancy Expected Years of Operation for 4300 of various powering options at equipment duty cycles
Model – Run Time, Idle, 2hrs/day, 8hrs/day, 24hrs/day 4300-3A – 10 yrs, 10 yrs, 10 yrs, 8.4 yrs
4300-3I – Indefinite operation when loop powered
4300-3O – Indefinite operation when loop powered
Display
Rate Display (selectable decimal) 5 Digits (99999), 0.35″ High, Display updates once per second with model 4300-3A, 8X per second with 4300-3I or 4300-3O
Rate Descriptors /SEC, /MIN, /HR for model
4300-3I/MIN, /HR, /DAY for models
4300-3A and 4300-3O
Min. Input Frequency 0.01 Hz to 10 Hz (selectable delay of 0.1 to 99.9 seconds)
Selectable Rate Display Damping
Totalizer Display (Selectable decimal)
8 Digits (99999999), 0.2″ High
Totalizer Descriptors Model 4300-3I: GAL, LIT, FT3, M3
Model 4300-3A and 4300-3O: GAL, BBL, MCF, M3
Warning Displays Low battery warning
Pulse Output The pulse output advances with the least significant digit
of the totalizer or decimal multiples there of (see Pulse
scale divider).
Type Isolated photomos relay
Max. voltage (off state) 30 VDC
Current (on state) 100mA
Pulse Duration Selectable 0.5, 0.25, 0.125, 0.0625 sec.
Pulse Scale divider (Pulscale) User selectable, ÷1, ÷10, ÷100 or OFF
Accuracy 0.01% Reading, ±1 count
Temperature Drift: 50 ppm/°C Worst Case
Environmental
Operating Temperature-4°F (-20°C) to + 158°F (70°C)
Extended Temp: -22°F (-30°C) to + 158°F (70°C)
Humidity0 – 90% Noncondensing
Enclosure style
Explosion ProofClass I, Division 1, Groups B, C & D
Class II, Division 2, Groups E, F & G
ApprovalsCSA/NRTL Explosion Proof Listed LR91109
Inputs
Magnetic Pickup InputFrequency Range: 0 to 3500 Hz
Trigger Sensitivity: 10 mV p-p
Over Voltage Protected: ± 30 VDC
Opto-Isolated DC Pulse Input High (logic 1): 4-30 VDC
Low (logic 0): Less Than 1 VDC
Minimum Current: .5 mA
Hysteresis: 0.4 VDC
Frequency Range: 0 to 5 kHz
Min. Pulse Width: 0.1 msec
Contact Closure Input (contact closure to common) Internal Pullup Resistor: 100 KÙ to +3.6 VDC
High (logic 1): Open or 4-30 VDC
Low (logic 0): Less Than .5 VDC
Internal Switch Debounce Filter: 0 to 40 Hz
Reset Input (contact closure to common) Internal Pullup Resistor: 100 KÙ to +3.6 VDC
High (logic 1): Open or 4-30 VDC
Low (logic 0): Less Than .5 VDC
Minimum On: 25 msec
K-Factor Range: 0.001 to 99999999
Decimal Point Locations: XXXX.XXXX to XXXXXXXX
20 Point Linearization
This feature allows the user to enter 20 different
frequencies with 20 different corresponding K-Factors
to linearize non-linear signals.
Analog Output (models 4300-3I And 4300-3O)
Type4-20 mA follows rate display, Two wire hookup
Accuracy0.025% Full Scale at 20° C
Temperature Drift50 ppm/°C Typical Reverse Polarity Protected
Update Rate8 times/second
Data Storage
Setup Information Stored in flash memory
Totalizer Stored in battery backed RAM but can be saved to flash
memory by operator for recall after battery change out.