HSS 1036 Hydro Surveillance System

The INVALCO HSS 1036 Hydro Surveillance System is a filter fluorescence photometer with a fixed excitation bandpass source (365 nm) and an emission bandpass filter (460 nm). It is designed specifically for the quantitation of low ppm concentration measurements of aromatic hydrocarbons (oil) in water.

The HSS 1036 uses a UV fluorescence technique to target the aromatic component of the oil contamination. Through a site calibration this aromatic tag provides an indication relative to total oil. The sample vial is placed into the sample well. A non-contacting UV light source targets the sample with filtered light energy. The soluble and emulsified oils in the water will excite from this light energy and fluoresce light energy back out of the water at a signature wavelength. The intensity of light energy at this wavelength is measured to provide an indication of the ppm concentration.

Overview

Features and Benefits

  • Solvent extraction qualifies sample to ISO and EPA methods
  • Fast sample preparation and immediate readings
  • Controlled and safe use of solvents Easy calibration and instrument set-up
  • Reading printout serial port
  • Bright backlit display of ppm readings
  • Long life lamp
  • No lag time, sample injection, or evaporation
  • Ideal for site screening and process trend monitoring
  • Compliments and supports existing laboratory results

Specifications

Power Requirements• Frequency: 47 – 63 Hz
• Line Voltage: 90 – 260 VAC
• Power Consumption: 15 W
User Interface2 line x 16 characters Backlit LCD, Membrane keypad
Communication PortRS232C, 9 pin male serial connector,1200 baud,
8 data bits, 1 stop bit, no parity
Dimensions 4.72 x 6.26 x 13.5 inches (12 x 15.9 x 34.3 cm) (h x w x d)
Weight 3.75 lbs (1.7 kg)
Operating EnvironmentIndoor Use 59°F to 104°F (15-40°C)
Relative Humidity• 80% for 59°F to 88°F (15 – 31°C)
• Decreasing linearly to 50% for 88°F to 104°F (31 – 40°C)
• Altitude: 6562 ft (2000 m)
Light Source• Type: Mercury lamp
• Excitation Wavelength: 365 nm ± 7 nm at Full Width Half
Maximum • Expected Life: 5000 hours
Emission Filter Type Ordering Information• Interference filter
• Emission Wavelength: 460 nm ± 15 nm at Full Width Half Maximum
Fuse Values (internal)F3.15 A, 250 V, Microfuse (2) on PCB; F2 A, 250 V, 5 x 20 mm on power module
Safety Specifications
Safety • UL3101-1
• CSA 22.2 No. 1010-1
• EN61010
Emissions • FCC Part 15 Class A
• EN55011 Class A
Immunity • EN50082-1
• Listed by ETL Testing Lab
• CE Marked

Downloads

Request
More Information

We welcome and value your feedback please feel free to contact us at the information below. We look forward to assisting you.