8950 Series: Back Pressure or Pressure Reducing, Overbalanced Valve

Application

This Series can maintain a constant pressure upstream (back pressure) or downstream (pressure reducing). The back pressure unit is used to maintain pressure on separators, vessels or any location where constant pressure is vital. The pressure reducing version is suited on gas lift operations to protect surface equipment and to replace fixed orifice devices. The 8950 Series is available in a 316L stainless steel 2” body to CF8M specification.

Specifications

Size:1″ 2″
Working Pressure:1500 psig 1500 psig
Temperature:-20ºF to +180ºF; available to +240ºF
Topworks:Pressed steel with nylon reinforced nitrile diaphragm. 50 psig maximum supply pressure.
Effective Area:45 sq. in. 62 sq. in.
Cv Factor:18 48
Trim:
Seat:
Plug:

Stainless steel, removable.
Steel with molded nitrile standard; optional fabricated acetal, polyurethane or TFE inserts.
Material:
Body:
Stem:
Packing:
Packing Block:

Cast steel standard, available in 316L stainless steel (2″ size)
Stainless steel
Poly Pak
Stainless steel

Downloads

Request
More Information

We welcome and value your feedback please feel free to contact us at the information below. We look forward to assisting you.